Product Code : CTR-5
SUPPLY/SENSING VOLTAGE.
225 - 475 V ac 2 phase & Neutral at U, V & N.
FREQUENCY.
50 Hz.
OUTPUT.at
F+,F-
Voltage.
Current.
Resistance
380 V dc @ 415 V ac input.
10.0 A, continuous / 20.0 A., transient for 10 secs.
15 ohms min.
REGULATION.
+/- 1.0%.
AVR RESPONSE.
20 ms.
UNDER Frq. PROTECTION.
Approx. 47 Hz settable by pot. Slop - 150% volts/Hz.
BULD UP VOLTAGE.
5 Volts @ AVR terminals.
OPERATING TEMPERATURE.
-40 to + 70 Degree C.
PROTECTION FUSE.
10.0 A, quick acting (19mm X 5mm glass cartridge)
V - Set.
To adjust generator output voltage.
Clockwise rotation increases output voltage.
Stab.
To prevent voltage hunting.
Clockwise rotation increases damping effect.
U/F SET
To set ufro nee point.
Clockwise rotation increases nee point setting.
O/L SET
To limit, max. DCV at F+,F-
Clockwise rotation increases DCV limit.
L x W x H
169mm X 106mm X 45mm
Weight.
480 gms.
MOUNTING.
6.6mmX 2holes,at center distance of 155.0mm.